Periodically, it is advisable to make sure that no dirt (leaves, sand, etc.) has accumulated in the collection
trap.
MAINTENANCE AND CLEANING
It is absolutely essential to prevent any risk of the pump freezing. In the event of freezing temperatures,
remove the pump from the liquid, empty it and keep it in a place where it cannot freeze.
The pump must be disconnected from the mains power supply before any cleaning operation is performed.
The pump is maintenance free.
5. TROUBLESHOOTING
Before taking any troubleshooting action, disconnect the pump from the power supply (i.e.
remove the plug from the socket).
If there is any damage to the power cable or pump, any necessary repairs or replacements must be
performed by the manufacturer or his authorized customer support service, or by an equally-qualified
party, in order to prevent all risks.
Fault
The motor does not
A) Make sure the motor is
start or makes no
noise.
B) The pump is not enabled by
The pump delivers no
A) The suction grid or piping are
water.
B) The impeller is worn or stuck.
C) The required head is too high
D) Water level under the suction
The pump does not
A) The pump is not disabled by
stop.
The flow rate is too
A) Make sure the suction grid is
low.
B) Make sure the impeller or
The pump stops
- Make sure the fluid being pumped
running (possible
is not too dense, causing the
intervention of the
motor to overheat.
thermal overload
- Make sure the temperature of the
switch).
water is not too high.
- Make sure there is no solid body
obstructing the impeller.
- Power supply doesn't comply
with the nameplate's data.
Possible causes
powered.
the float.
clogged.
for the characteristics of the
pump.
minimum.
the float.
not partially clogged.
delivery pipe are not partially
clogged or fouled.
6
Solutions
B) - Make sure the float can move freely.
- Increase the depth of the pit.
A) Remove the obstruction.
B) Replace the impeller or remove the
obstruction.
A) Make sure the float can move freely.
A) Remove any obstructions.
B) Remove any obstructions.
Disconnect the power cord, correct the
reason for overheating; then wait until the
pump is cooled, plug the cord and resume
operation.
GB