DAB FEKAFOS 280 Instructions For Installation Manual - Page 16

Browse online or download pdf Instructions For Installation Manual for Water System DAB FEKAFOS 280. DAB FEKAFOS 280 19 pages.

DAB FEKAFOS 280 Instructions For Installation Manual
7
Floats:
The floats (two for FEKAFOS 280 l three for FEKAFOS 280-550 DOUBLE) are already installed and with their
height set inside the tank.
Pass the float connecting cables through the fairleads preassembled on the tank (detail 7, fig. 10), tighten the ring
nut and connect the cable to the control panel as indicated in the respective manual, taking care that the terminals
on the panel correspond to the respective float cables.
TWO FLOATS
CONT ROL PANEL
BROWN
GREY
BLUE NOT
NOT US ED
USED
MIN
MIN
No. CABLE CLAMPS FITTED
FEKABOX 200
FEKAFOS 280
FEKAFOS 280 DOUBLE
FEKAFOS 550 DOUBLE
1
2
3 4
A B
BLACK
BROWN
BLACK
GREY
BLUE NOT
NOT US ED
USED
MAX
MAX
ENGLISH
For Fekafos 280/280D for cables sec ≥ 4G1.5mm2
1
4
6
6
THREE FLOATS
CONT ROL PANEL
BROWN
BLACK
GREY
GREY
BLUE NOT
BLUE NOT
NOT US ED
NOT US ED
USED
USED
MIN
51
Fig. 10
1
2 3 4
5
6
A B
BROWN
BLACK
BLACK
BROWN
GREY
BLUE NOT
NOT US ED
USED
MAX
MED