3.
APPLICATIONS
The Active Driver M/T is fed with a single-phase line and it drives electropumps with a standard three-phase 230V
asynchronous motor.
The Active Driver M/M is fed with a single-phase line and it drives electropumps with a standard single-phase 230V
asynchronous motor.
The Active Driver T/T is fed with a line three-phase and it drives electropumps with a standard three-phase 400V
asynchronous motor.
4.
TECHNICAL DATA AND LIMITATIONS OF USE
− Max phase current of the motor:
− Line voltage:
− Line frequency:
− Electropump voltage:
− Weight of the unit
(packing excluded):
− Work position:
− Max fluid temperature:
− Max working temperature:
− Max. pressure:
− Regulating range:
− Maximum dimensions (LxHxD):
− Fluid input hydraulic coupling:
− Fluid output hydraulic coupling:
− Degree of protection:
− Protections:
5.
ELECTRICAL CONNECTIONS OF THE ACTIVE DRIVER TO THE ELECTROPUMP
5.1
Ensure that all the terminals are fully tightened, paying particular attention to the earth
terminal .
5.2
Check that all the connecting cables are in excellent conditions, with the external sheathing
unbroken.
5.3
The motor of the installed electropump must comply with the data in the table in Chapter 4.
The user connected to the ACTIVE DRIVER M/M 1.1 must not exceed 8,5 A as phase current.
The user connected to the ACTIVE DRIVER M/T 1.0 must not exceed 4,7 A as phase current.
The user connected to the ACTIVE DRIVER M/T 2.2 must not exceed 9,3 A as phase current.
The user connected to the ACTIVE DRIVER T/T 3.0 must not exceed 7,5 A as phase current.
The user connected to the ACTIVE DRIVER T/T 5.5 must not exceed 13,3 A as phase current.
5.4
Connect the electropump to the output cable of the ACTIVE DRIVER, paying particular attention to
the earth connection.
The incorrect connection of the earth lines to a terminal other than the earth terminal
may cause irremediable damage to the whole appliance!
The incorrect connection of the power supply line on output terminals intended for the
load may cause irremediable damage to the whole appliance!
6.
CONNECTION TO THE POWER SUPPLY LINE
6.1
Connect the ACTIVE DRIVER to the power supply line by means of the power socket.
(See values in chapter 4).
6.2
If an extension to the power cable is used the following minimum sections must be respected:
Section of each lead (mm²)
ENGLISH
A.D. M/M 1.1
8,5 A
230 V
single-phase
50-60 Hz
230 V
single-phase
4 Kg.
Any position
50°C
60°C
10 bar
from 1 to 6 bar
22x28x18 cm
1 ¼" male
1 ½"female
IP 55
-
dry running
-
overload
-
excess temperature of the electronics
-
abnormal feeding voltages (excluding A.D. M/M and A.D. M/T 1.0)
-
direct short-circuit between the output phases
Maximum length of the line (metres)
1.5
2.5
4
26
A.D. M/T 1.0
A.D. M/T 2.2
4,7 A
9,3 A
230 V
230 V
single-phase
single-phase
50-60 Hz
50-60 Hz
230V
230 V
three-phase
three-phase
3,8 Kg.
3,8 Kg.
Any position
Any position
50°C
50°C
60°C
60°C
10 bar
10 bar
from 1 to 9 bar
from 1 to 9 bar
22x28x18 cm
22x28x18 cm
1 ¼" male
1 ¼" male
1 ½"female
1 ½"female
IP 55
IP 55
15
30
60
A.D. T/T 3.0
A.D T/T 5.5
7,5 A
13,3 A
400 V
400 V
three-phase
three-phase
50-60 Hz
50-60 Hz
400 V
400 V
three-phase
three-phase
5 Kg.
5Kg.
Facing upward
Facing upward
50°C
50°C
60°C
60°C
10 bar
10 bar
from 1 to 9 bar from 1 to 9 bar
22x28x18 cm
22x28x18 cm
1 ¼" male
1 ¼" male
1 ½"female
1 ½"female
IP 55
IP 55