7. TROUBLESHOOTING
Table 7.1. Possible faults, their causes and solutions
Problem
Leveler does not
rise (pump does not work)
Leveler does not
rise (pump works)
Leveler does not lower
6
Possible cause
No supply voltage
Faulty power switch
Blown fuse
Faulty contactor
No power to the contactor coil
No jumper on terminals
for safety devices
Interlock switch open
Leveler does not respond to pressing the
control button
Incorrect phasing
No power to the electromagnetic valve coil
Faulty electromagnetic valve coil or valve
Solution
Check the electrical wires
and the voltage in the socket
Replace main power switch
Replace fuse (FU1, FU2)
Replace main board
Replace main board
Set the jumper
Check the interlock
Replace control board
Swap any two phases in the control unit
Check wiring from control unit to coil.
Check coil voltage (24 VDC)
Replace main board
Replace coil or valve