1.2. CONTROL UNIT TERMINALS DESCRIPTION
TYPE
COLOUR
Jack
ХP9
ХP7
ХP3
ХP8
ХP6
ХP2
ХP1
TERMINALS
№
MEANING
«full opening» command. After closing of contacts of the device connected
1
Open
to this terminal, the control unit will trigger either full opening of the door or
stepped control of operator (depending on the preset control logic).
«close» command. After closing of contacts of the device connected to this
2
Close
terminal, the control unit will trigger door closing
3
Com
Common contact
«stop» command. After breaking of contacts of the device connected to this
1
STOP
terminal, the control unit will stop door movement.
Contacts for safety device connection (NC). Safety devices are used to
prevent people, animals and foreign objects
from being jammed in the door opening by the moving door leaf. Activation
2
PHCL
of safety devices immediately stops or reverses the
door. If sensors of the safety devices responded when the door was open,
that will prevent any movement of the door..
3
COM
Common contact
Terminal for connecting of end switch which is responsible for extreme
1
SWCL
position to closing on cloth.(Red wire from end switch)
Terminal for connecting of end switch which is responsible for extreme
2
SWOP
position to opening on cloth.(Green wire from end switch
Common contact
3
COM
(White wire from end switch)
1
(-)
For accessories power supply.
2
+24 В
1
Terminals for connecting of signaling lamp ~ 220V. This split is only
LAMP
present on board of version 1.1.
2
1
N
Common terminal of electromotor
2
L1
Terminal on closing of electromotor
3
L2
Terminal on opening of electromotor
1
N
Connecting of mains supply ~ 220V
2
L
ELECTRICAL INTERFACES
CONNECTING DEVICES
9