DoorHan PCB-SW 24 Programming Instructions Manual - Page 17

Browse online or download pdf Programming Instructions Manual for Control Panel DoorHan PCB-SW 24. DoorHan PCB-SW 24 20 pages.

DoorHan PCB-SW 24 Programming Instructions Manual
Menu item
0.1
0.2
0.3
0.4
Preliminary signal lamp switching on (5 sec.): 1 – 1 sec.; 2 – 2 sec.; 3 – 3 sec.; 4 – 4 sec.; 5 – 5 sec.
0.6
0.7
Door opening/closing when buttons are pressed and hold (control commands from remote control are not executed):
0.8
0.9
1.0
1.1
Time of switching off of OUT1 output additional lighting after stop in: 0 – 0 sec.; 1 – 10 sec.; 2 – 20 sec.; 3 – 30 sec.;
1.2
1.3
1.4
1.5
1.6
1.7
1.8
9.8
9.9
Parameter
Operation mode
value
0
Accessories power supply
Indicator lamp for on mode
1
during opening
2
Additional lighting
3
Traffic light mode
4
Switch on during opening
5
Switch on during closing
Output control by OUT(n)»
6
command
Output impulse control by
7
OUT(n) command
*see p. 1.2, table 3.2
NOTE.
Before learning the door leaves are closing, when they reach the door stopper operator setting starts.
Start operator learning with the motor switched to M1 output to make one-leaf mode automatic.
Function description
Force at the 1st leaf: 1 – minimum force; 6 – maximum force
Force at the 2nd leaf: 1 – minimum force; 6 – maximum force
Maximum force at the initial moment: Y – function is on; n – function is off
Photocell response for closing:
Y – door reverse movement after opening clearing; n – instant reverse
Automatic door closing after photocells response:
Y – function is on; n – function is off
Y – function is on; n – function is off
Prohibition on receiving control commands during door opening:
Y – function is on; n – function is off
Separate control logic:
START command – door opening and stop;
PEDESTRIAN command – door closing and stop;
Y – function is on; n – function is off
OUT1 universal output operation logic (see table 3.3)
4 – 60 sec.; 5 – 90 sec.; 6 – 120 sec.; 7 – 180 sec.; 8 – 360 sec.; 9 – 420 sec.
Remote recording of remote controls: Y – function is on; n – function is off
Control command type of remote control button 1
Control command type of remote control button 2
Control command type of remote control button 3
Control command type of remote control button 4
Door quick movement function: Y – function is on; n – function is off
Parameters reset to factory settings
Software version
Open
On
On
On
(selected time*)
On
Off
Off
Table 3.3. Operation logic of the universal output
Opening
Stopped
On
On
On
On
On
On
(selected time*
Off
Off
On
Off
Off
Off
Switch on / switch off logic
1 second impulse
OPERATOR PROGRAMMING
Table 3.2. Advanced programming
Default
Closing
Closed
On
On
Flashing
Off
On
On
(selected time*
Off
Off
Off
Off
On
Off
3
3
n
0
n
n
n
n
n
2
0
Y
0
0
0
0
n
rE
17