DoorKing 9230 Quick Start Manualline - Page 2
Browse online or download pdf Quick Start Manualline for Gate Opener DoorKing 9230. DoorKing 9230 2 pages. Mounted on the pedestal mounting stand
QUICKSTART "BASIC" GUIDELINES FOR MODEL 9200 - DIP-SWITCH AND WIRING REFERENCE
This vehicular gate operator is designed for Class III and Class IV applications only and
must never be used in applications serving the general public.
For safety and installation instructions, please refer to the Installation/Owner's manual.
SW 1 DIP-Switches (Right Hand Side)
Switch
Function
Setting
Changes the direction
1
the operator will
open/close the gate.
OFF
Auto-Close
2
Timer
ON
Exit Loop Port
OFF
Jumper Wire
Needed
3
Output
See Manual
SW 1
Full Open Input
ON
Upside-Down on Circuit Board.
4-OFF
5-OFF
Relay Activation
and
4-OFF
5-ON
4 and 5
LED Indicator
4-ON
5-OFF
Light Activation
4-ON
5-ON
Warn Before
OFF
6
Operate
ON
OFF
7
Reverses Gate
Stops Gate
ON
OFF
Quick-Close
8
ON
Timer Override
SW 2 DIP-Switches (Left Hand Side)
Switch
Function
Setting
OFF
1
Self-Test
ON
OFF
Gate Opens
SW 2
2
Uphill
ON
Upside-Down on Circuit Board.
OFF
Gate Opens
3
Downhill
ON
SW 1 - Right 8 Switches
Description
Opening direction
Opening direction
using ON setting.
using OFF setting.
Lower Configuration
Auto-close timer is OFF. Manual input required to close gate.
Auto-close timer is ON. Adjustable from 1-23 seconds to close gate.
The output wired to terminal #4 becomes the output from the loop detector
installed in the EXIT loop port. Plug-in loop detector required for "OFF" function.
Normal Setting. Terminal #4 is a normal full open input for a single gate operator.
Relay activates and LED is ON when the gate is fully open.
Relay activates and LED is ON when the gate is not closed.
Relay activates and LED is ON when the gate is opening and open.
Relay activates and LED is ON when the gate is opening and closing.
Internal alarm will NOT sound.
Internal alarm will sound before gate starts and throughout gate's cycle.
Normal Setting. Input to terminal #6 and/or reverse loops will REVERSE gate
during CLOSE cycle.
Input to terminal #6 and/or reverse loops will STOP gate during CLOSE cycle.
Normal Setting. Timer will function normally.
Opening gate will stop and begin to close as soon as all reversing inputs (Reverse
loops, photo sensors) are cleared regardless of the distance the gate has opened.
Note: After a DIP-switch setting is changed, power must be turned
OFF and then turned back on for the new setting to take affect.
SW 2 - Left 3 Switches
Description
Normal Setting. Normal gate operation.
Self-test mode. Operator MUST be disconnected from gate to run self-test.
Normal Setting. Normal gate operation.
MUST be ON if gate opens UPHILL.
Normal Setting. Normal gate operation.
MUST be ON if gate opens DOWNHILL.
Important:
Controls intended for user activation must be located at least six (6) feet away from any moving part
of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the
controls. Emergency access controls only accessible by authorized personnel (e.g., fire, police, EMS) may be
placed at any location in the line-of-sight of the gate.
Main Terminal
Entrapment Protection must be
4404-018
provided for the gate system where
the risk of entrapment or
obstruction exists.
The operator will NOT run without
one or more monitored type B1 or
B2 external entrapment protection
devices in EACH direction of gate
travel (minimum of 2 external
20 19 18 17 16 15 14
devices required).
Com
Note: All stand-alone and
telephone entry devices
must use a separate
power source.
3-Button Control Station Switch
Switch in RIGHT position ONLY
when using a 4-wire 3-button
control station with a
normally closed STOP circuit.
SW 1 is Upside-Down on Board
SW 1, Switch 3 MUST be
External Entrapment Protection Devices
ON except for dual
operators or exit loop partial
open applications.
IMPORTANT:
Only 1 monitored Device can be connected to each
input. An OPTIONAL Expansion Kit (sold separately) will allow
connection for additional devices.
IMPORTANT:
Photo sensors must use Normally Closed (NC) contacts with the beam
set for light operate (relay activated when beam is not obstructed). Some
manufacturer's photo sensor contacts are labeled as Normally Open (NO) but their
relay functions the same way as described above. See specific manufacturer's wiring
manual for more information about their specific relay function.
Close Beam
Open Edge
Closed Gate
Telephone Entry
Key Switch
UL 325 DIP-Switches
OPEN Beam
CLOSE Beam
OPEN Edge
Stand-Alone
CLOSE Edge
Keypad
DIP-switches MUST be turned ON
for each device wired to terminal.
Connect ONLY MONITORED Devices
Stand-Alone
Card Reader
UL 325 August
2018 Standard
UL 325
DIP-Switches
UL 325 Terminal
6
5
4
3
2
1
3-Button Control Station Switch
13
12 11
10 9 8
7
6
5 4 3 2 1
Com
Open
Close
Stop (NC)
3-Button Control Station
Wall
Filler Post If necessary
Open Beam
UL 325 Terminal
#1-Com
#2 or #5-Relay
#3-24 volt
250 mamp. max.
6
5
4
3
2
1
#1-24 Volt Power Com
#1-Relay Com
#2 or #5-Relay
Com
#3-24 Volt Power
N.C.
N.C.
#5 Terminal Note: Any opening device
N.C.
connected to terminal #5 will open the gate to
N.C.
the partial open setting. External entrapment
N.C.
protection devices will also open the gate to the
partial open setting. If the Inherent Reverse Sensor
To #4 or #5
gets activated during the close cycle, it will always
fully open the gate.
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
Auxiliary
Common
Terminal
Connect any
common wire to
these 2 terminals.
2-Pin Supplied
Wire Harness
Fire
Dept
Open
Gate will ONLY OPEN when this device
is activated by authorized personnel
ONLY (fire, police, EMS) and operator
has power. Alarm will sound during
entire open cycle. Operator will then go
into a hard shutdown once fully opened.
Operator MUST be reset to function
normally again. This device MUST be
mounted in the line-of-site of gate so
authorized personnel can monitor gate
movement.
Activation Note: Activation of this
device will OPEN gate regardless of the
status of the open direction monitored
external entrapment protection
device(s). If gate is opening, and the
operator's inherent entrapment
protection system detects an
obstruction, the operator will reverse
approx. 2 inches and go into a hard
shutdown. Operator reset button MUST
be pushed to function again OR cycle
operator's power.
Main Terminal #3 Note: Exceeding 250 mA of
power from this terminal may cause the
circuit board transformer to overheat, causing
intermittent problems.
3-Wire Radio Receiver
4-Wire
Radio Receiver