Canon PIXMA MX350 Simplified Service Manual - Page 11

Browse online or download pdf Simplified Service Manual for All in One Printer Canon PIXMA MX350. Canon PIXMA MX350 35 pages. Cartridge reset
Also for Canon PIXMA MX350: Installation Manual (17 pages), Install Manual (11 pages), Network Setup Manual (34 pages), Network Setup Manual (16 pages), Brochure (2 pages), Network Installation Manual (24 pages), Network Installation Manual (17 pages), Manual (4 pages)

Canon PIXMA MX350 Simplified Service Manual
Error
TX /
code
RX
##762 TX
After transmitting PPS-EOM in ECM transmission,
DCN has been received.
##763 TX
After transmitting PPS-EOM in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed,
or T5 time-over (60 sec.) has occurred.
##764 TX
After transmitting PPS-EOM in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##765 TX
After transmitting PPS-EOP in ECM transmission,
no significant signal has been received, and
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##767 TX
After transmitting PPS-EOP in ECM transmission,
DCN has been received.
##768 TX
After transmitting PPS-EOP in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed,
or T5 time-over (60 sec.) has occurred.
##769 TX
After transmitting PPS-EOP in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##770 TX
After transmitting EOR-NULL in ECM transmission,
no significant signal has been received, and
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##772 TX
After transmitting EOR-NULL in ECM transmission,
DCN has been received.
##773 TX
After transmitting EOR-NULL in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed,
or T5 time-over (60 sec.) has occurred.
##774 TX
After transmitting EOR-NULL in ECM transmission,
ERR has been received.
##775 TX
After transmitting EOR-MPS in ECM transmission,
no significant signal has been received, and
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##777 TX
After transmitting EOR-MPS in ECM transmission,
DCN has been received.
##778 TX
After transmitting EOR-MPS in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed,
or T5 time-over (60 sec.) has occurred.
##779 TX
After transmitting EOR-MPS in ECM transmission,
ERR has been received.
Meaning
(10/37)
Solution
(parts that are likely to be faulty)
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
- Try a higher transmission level.
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.