Air Dimensions Incorporated Dia-Vac R Series Operating Instructions Manual - Page 3

Browse online or download pdf Operating Instructions Manual for Water Pump Air Dimensions Incorporated Dia-Vac R Series. Air Dimensions Incorporated Dia-Vac R Series 11 pages. Elevated/extended pump with explosion proof motor

Air Dimensions Incorporated Dia-Vac R Series Operating Instructions Manual
 
Operation 
No oiling or other lubrication is necessary with a Dia‐Vac® pump. 
 
If the gas stream has a high level of particulate matter, a filter should be installed before the pump. If the 
gas stream has a high level of liquid matter, a membrane separator should be installed before the pump. 
This should be used in conjunction with best practices for pump installation including mounting the pump 
head so that the discharge port faces toward the ground. Keep in mind that the pump head can be rotated 
in any direction on the housing. The gas will always flow in the direction of the arrows on top of the head.  
 
The elevated and extended pumps are for use in hazardous areas where heated heads cannot be used to 
prevent condensation buildup in the pump. These pumps are designed to have head or heads mounted 
in a heated enclosure to prevent condensation of vapors within the pump head. The plate of either of 
these pumps can hold the entire weight of the pump. 
 
This pump can be mounted in any position. If the housing needs to be rotated for mounting purposes, 
that can be done at the ADI facility. 
 
Do not start the pump against pressure or vacuum. For applications that must start under pressure or 
vacuum, contact ADI and a suitable motor will be selected. 
 
Running amps are listed on the nameplate of the motor. A pump running at a substantially higher current 
than shown on the motor plate indicates a problem, please see section "Troubleshooting" below. Please 
note that the current draw at the startup of the pump will be three to four times the normal running 
amps. 
 
For high pressure applications, outlet pressures above 15 psig, please consult an ADI representative for 
proper motor sizing. 
  
The  pump  is  designed  for  atmospheric  pressure  or  vacuum  on  the  inlet.  For  applications  with  inlet 
pressure greater than 0 psig; contact ADI and a suitable pump will be selected.  
 
The diaphragm, valve discs, sealing washer, and gasket are the only consumable parts of the pump. The 
degree  of  usage  and  condition  of  operating  temperatures  or  pressure  will  determine  the  rate  of 
replacement of part or parts. For heavy loads (25‐75 PSI) and constant operation the diaphragm should 
be inspected at least every six months. For lighter loads (0‐15 PSI or up to maximum vacuum) or pumps 
with reduced eccentric the diaphragm may operate successfully for a year or more. The corrosive content 
of the gas media being pumped can affect the recommended inspection and replacement cycle of the 
diaphragm. 
 
The minimum performance acceptable of a single head of an R‐series pump is shown in the table below. 
Pumps operating at 50 Hz have a 17 percent lower flow rate than their 60 Hz counterparts.  To check 
pumping  efficiency,  employ  suitably  damped  gauges  connected  so  as  to  dead‐head  either  pressure  or 
vacuum.