dacell AM-1000 User Manual - Page 11
Browse online or download pdf User Manual for Amplifier dacell AM-1000. dacell AM-1000 18 pages. Dynamic strain amplifier
4. 조작 방법
How to operate
4-1.
○
Please only use the exclusive AC code (3-tube) for the power cord. When AC
1
is not grounded, please make the connection by using the ground connector
which is located on the backside of lamp.
○
Please check the AC power selecting switch and then supply power to the
2
device. If the lamp is not lighted, please check the fuse and power selecting
switch.
4-2. Sensor connection
Connector is MIL-C- MS3112(14-19) connector of MIL-C-26482 Series. (contact
resistance, insulation resistance is superior)
<MS3112 14-19>
Pin No.
A
Excitation +
B
Excitation Sense +
C
Excitation –
D
Excitation Sense -
E
Signal +
F
Signal -
G
Shield
H
HB
J
D350Ω
K
D120Ω
L
R3
M
null
N
R4
P
null
R
null
S
null
T
null
U
null
V
Chassis GND
10
Use