dacell AM-1000 User Manual - Page 5
Browse online or download pdf User Manual for Amplifier dacell AM-1000. dacell AM-1000 18 pages. Dynamic strain amplifier
○
Temperature range for use
17
0 ~ +60°C
○
Effect by temperature change
18
Zero drift : within ± 1 µstrain/°C
Sensitivity change: ± 0.03% F.S/°C
Effect by electric power change (About ± 10% change in supply voltage)
○
19
Zero drift: within ± 0.05% F.S
Sensitivity change: within ± 0.05% F.S
○
MONITOR : Digital Voltage Display
20
Over 10V will be displayed in 10.00 (increased or decreased in each 0.01)
Less 10V will be displayed in 0.000 (increased or decreased in each 0.001)
Voltage on OUT1 will be displayed in Digital.
○
Supply Voltage
21
AC100/220V ± 10% 60Hz
○
External Size and Weight
22
128.4 (H) × 43.2 (W) × 198 (D) mm
1000g
○
OPTION
23
Output: OUT1 ± 100mA output
4