Astralpool 25462 Installation And Maintenance Manual - Page 7
Browse online or download pdf Installation And Maintenance Manual for Water Pump Astralpool 25462. Astralpool 25462 16 pages. Self-priming pump for pools
2.2 HYDRAULIC PIPING
• Observe the direction of the hydraulic connections.
• Select the pipe size according to the size of the pool in line with the hydraulic standards in place in
the country of installation.
• For hydraulic connections, use the standard connections required.
• Fit a check valve if the filter is installed above the water level.
• Fit isolation valves (suction and discharge) if the pump is installed below the water level.
• To avoid problems with priming, install the suction pipe so that there are no high points where air
can build up.
• Check that the hydraulic connections are securely tightened and that there are no leaks.
• The piping should be well supported to avoid any risk of breakage due to the weight of the water.
A
Pump
• Use as few elbow joints as possible. If there must be more than 10 elbow joints in the hydraulic
circuit, the diameter of the piping must be increased.
Installation and general maintenance manual
A
HYDRAULIC FITTINGS
B
Filter
Heating system
- SELF-PRIMING POOL PUMPS
C
B
C
Water treatment system
D
D
7