Section 3. Plumbing
CONTROLLER
HEATER
CHECK
VALVE
POOL RETURN
Figure 3.
Plumbing Cell Only
The cell must be plumbed in a position that is
accessible for maintenance and within 1.5 meters
of the controller. The cell should be the last piece of
equipment in the circulation system. The cell must
be installed horizontally, level and with correct flow
orientation, see Figure 3.
1.
If you intend to plumb the cell on a bypass, the bypass
must be equipped with Isolation valves, see Figure 3.
2.
Plumb the cell inlet and outlet on vertical lengths of 50
mm PVC pipe (if using 40mm pipe, use the provided
40mm reducers). The cell inlet and outlet ports are
11.5 cm apart, see Figure 2. The inlet of the cell is on
the side closest to the electrical lead, see Figure 4.
3.
Put the lock nuts onto the inlet and outlet pipes in the
correct orientation, see Figure 4.
4.
Glue the unions directly onto the pipes.
5.
Ensure the o-rings are seated properly on the unions.
6.
Secure the cell to the plumbing by tightening the
unions hand tight. DO NOT OVERTIGHTEN.
7.
Double check cell orientation. The cell inlet is closest
to the cell electrical lead.
WARNING
• The cell must be installed horizontally and level.
Improper installation can lead to gas build up which
could result in equipment damage or serious injury.
• The cell must be the last piece of equipment on the
return line, see Figure 3.
• It is recommended in all installations that the cell is
installed on a bypass equipped with isolation valves,
see Figure 3.
• In order to avoid load loss, installing the cell on a
bypass is MANDATORY if system flow rated exceeds
300 Lpm, see Figure 3.
• If installing on a bypass, use a downstream check
valve instead of a manual valve to prevent improper
back flow into the cell.
e series saltwater chlorinator
SPA RETURN
FILTER
PUMP
CELL
Cell
Adapter O-ring
Unions
Lock Nuts
Figure 4.
Cell Plumbing Assembly
Installation Manual
POOL/SPA
3 WAY VALVE