DOOVAC SML-280 User Manual - Page 7

Browse online or download pdf User Manual for Water Pump DOOVAC SML-280. DOOVAC SML-280 11 pages.

DOOVAC SML-280 User Manual
Since connecting is dangerous work, only a qualified engineer may carry out
power connection work, in compliance the following standards;
IEC 364, CENELEC HD 384, or DIN VDE 0100
WARNING
-
-
The power cable must have sufficient capacity for the electric motor power.
Make sure to provide an electronic contact, overload protector, and ground cable.
CAUTIO N
When connecting 3-phase power supply, make sure that the motor rotates in the
direction marked on the casing.
CAUTIO N
Install a reverse rotation protector to prevent reverse rotation.
2-2) Wiring: 3-phase
If the direction of rotation is not correct under 3-phase wiring, change the wiring of 2-phase.
3. Inle t and O utlet Connection
Remove the rubber plugs and check the cleanliness of the pipes before connecting the inlet and
IEC-Report 664, DIN VDE 0100
BGA A2 (VBG4) or applicable regulations of the region.
Delta connection
Low Voltage (220V)
Y -connection
High Voltage (380V)
2-2-1) Wiring: single phase
Low Voltage (110V)
High Voltage
(220V)