Ames Instruments 64013 Owner's Manual & Safety Instructions - Page 9

Browse online or download pdf Owner's Manual & Safety Instructions for Measuring Instruments Ames Instruments 64013. Ames Instruments 64013 16 pages. Digital clamp meter. ac 600v cat iii

NcV (Non-contact Voltage)
1.
Turn Rotary Switch to any position.
2.
Hold the NcV button and move the tip
of the clamp close to the unshielded
conductor. If detected voltage is >110V
AC, Meter will beep and the Non-
Contact Voltage Indicator will flash.

Auto power Off

If Meter is not used for approximately 30 minutes, it will automatically turn itself off to
conserve battery power. To turn Meter back on after auto-off, press the SEL button.
Item 64013
For technical questions, please call 1-888-866-5797.
WARNING! Even if no indication is
given, voltage may still be present.
Do not rely solely on NCV detection to
determine the presence of voltage.
Page 9