Specifications
DC Voltage
DC Voltage Accuracy
AC Voltage
AC Voltage Accuracy
AC Current
AC Current Accuracy
Resistance
Resistance Accuracy
Diode
Continuity
Capacitance
Capacitance Accuracy
Frequency
Frequency Accuracy
Sampling Rate
Operating Temperature
Operating Humidity
Jaw Opening
Display
Battery
Item 64020
Ranges: 400mV / 4V / 40V / 400V / 600V
(@ 400mV) ± 1.0% of rdg + 8D
(@ 4V) ± 0.8% of rdg + 1D
(@ 40V, 400V) ± 0.8% of rdg + 3D
(@ 600V) ± 1.0% of rdg + 3D
Ranges: 4V / 40V / 400V / 600V
Frequency Range: 40Hz - 400Hz
(@ 4V, 40V, 400V) ± 1.2% of rdg + 5D
(@ 600V) ± 1.5% of rdg + 5D
Ranges: 4A / 40A / 400A
Frequency Range: 50Hz - 60Hz
(@ 4A) ± 2.5% of rdg + 30D
(@ 40A) ± 2.5% of rdg + 5D
(@ 400A) ± 1.8% of rdg + 9D
Ranges: 400Ω / 4kΩ / 40kΩ / 400kΩ / 4MΩ / 40MΩ
(@ 400Ω) ± 1.2% of rdg + 2D
(@ 4kΩ, 40kΩ, 400kΩ) ± 1.0% of rdg + 2D
(@ 4MΩ) ± 1.2% of rdg + 3D
(@ 40MΩ) ± 2.0% of rdg + 5D
Forward DC Current: ~1mA
Reverse DC Voltage: 1.5V
Meter beeps at < 30Ω
Ranges: 50nF / 500nF / 5μF / 50μF / 100μF
(@ 50nF) ± 4.0% of rdg + 25D
(@ 500nF, 5μF, 50μF, 100μF) ± 4.0% of rdg + 5D
Range: 10Hz - 1MHz
± 0.1% of rdg + 4D
~3 times/second
Range: 32° - 86°F
32° - 86°F ≤ 80% RH
87° - 104°F ≤ 75% RH
105° - 122F° ≤ 45% RH
30mm
LCD
3 AAA (included)
For technical questions, please call 1-888-866-5797.