Variable Flame Height Adjustment
1. All appliances are equipped with a variable
gas control valve. Flame height for these
models may be adjusted through a range
between fixed low and high settings, alter-
nately, while the appliance is in operation.
Adjust the flame height as desired after
lighting the appliance by rotating the variable
adjustment control knob located on the front
of the valve (see Figure 2).
2. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This
is due to the "burn-in" of internal paints
and lubricants used in the manufacturing
process.
3. Keep lower control compartment clean by
vacuuming or brushing at least twice a year.
More frequent cleaning may be required due
to excessive lint from carpeting, bedding
materials, etc. It is important that control
compartments, burners and circulating air
passageways of the appliance be kept clean.
S'assurer que le brùleur et le compartiment
des commandes sont propres. Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'appareil.
4. Always keep the appliance area clear and
free from combustible materials, gasoline
and other flammable liquids.

Maintenance

The appliance should be thoroughly inspected
before initial use and at least annually by a quali-
fied service technician. However, more frequent
periodic inspections and cleanings should be
performed by the homeowner. Homeowner
must contact a qualified service technician at
once if any abnormal condition is observed.
Refer to the maintenance schedule for main-
tenance tasks, procedures, periodicity and by
whom they should be performed. Always verify
proper operation of the appliance after servicing.
IMPORTANT: TURN OFF GAS AND ANY ELEC-
TRICAL POWER BEFORE SERVICING THE
APPLIANCE.
Battery Replacement
The intermittent ignition system operates on 3
volts provided by two (2) "D" cell batteries. The
batteries are located in a pack installed within
the J-Box, behind the stainless ON/OFF switch
panel. Refer to Figure 3.
NOTE: All batteries loose voltage when frozen
or left for prolonged periods. It may be wise
to remove batteries during extended periods
of disuse.
Pilot Stage
Terminal
Ground
(TP)
Gas Outlet
To Burner
Burner Stage
Regulator
Terminal
Mounting Screw
Figure 2 - Dexen Electronic Gas Valve
Weather Seal
Cover
Switch
Figure 3 - Battery Replacement
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Pressure-Tap
Pilot Gas
(Inlet)
Outlet
HI
LO
Pressure-Tap
(Manifold)
Orient Batteries Vertically
To Fit Within Box
Supply
Gas
Inlet
5