AIR GAP GAP-A-RO, KIT S-A Installation Procedures - Page 2
Browse online or download pdf Installation Procedures for Industrial Equipment AIR GAP GAP-A-RO, KIT S-A. AIR GAP GAP-A-RO, KIT S-A 2 pages. Reverse osmosis air gap
1- Inline Reverse Osmosis Air Gap Drain
1- Mounting Bracket
4- 3/8 Nylon Clamps
6- #6-1", Phillips Screws
AG110-001 Reverse Osmosis Filter Air Gap prevents back-flow from drain line into RO
system. The discharge water flows out of the reverse osmosis system into inlet, passes air-gap,
and then down to the drain piping.
•Secure connection of inlet and outlet ports using 3/8-inch poly-tubing.
•Tested at over 0.3 GPM (1.1 Liters/minute)
•The optimum suggested usage 1 to 16 oz/minute (30 to 500 milliliters/minute)
•UPC® listed, tested for compliance to IPC and NSF standards
Please read the instructions once through before starting.
AG110-001 INSTALLATION INSTRUCTION
1. Make sure that the flow rate output of the RO equipment meets AG110-001 flow capacity limits such as
0.3 GPM (1.1 Liters/minute).
2. Check inlet and outlet ports marking on AG110-001 body and install AG110-001 into the threaded opening of the
mounting bracket as shown on FIG 1-1 (mounting options 1 and 2), for dimensions see FIG 1-2.
Inlet Port
Mounting option 1
Inlet Marking
Inline Reverse Osmosis
air gap
Outlet Marking
Mounting Bracket
Outlet Port
Fig 1-1
Discharge
AG110-001
RO System
Drain Pipe
AG110-001
Installation Procedures
LIST OF PARTS ENCLOSED
Always comply with local plumbing codes during installation
Inlet Port
Mounting option 2
Outlet Port
Water supply
RO Tank
Water Cooler
Inlet Marking
Inline Reverse Osmosis
air gap
Outlet Marking
Mounting Bracket
3. AG110-001 is a gravity flow device and must have an
outlet poly tubing feeding directly to a drain without kinks
or bends. The AG110-001 must be permanently
connected to enable the discharge water to flow freely
through the outlet tubing. (See FIG 1-3)
Fig 1-3
-OVER-
-OVER-
4 1/2"
0.680" dia.
0.640" dia.
2.85"
1"
Fig 1-2