4. Clear All Die #'s and Positions: This function lets you clear all die numbers and shut height values without affecting the
other functions. Simply select "PROG" mode and depress: F - 7 - 5 - 3 - ENT.
This will remove all die numbers and position values.
5. Remove a Specifi c Die # and Position: To remove a specifi c die, select "PROG" mode and depress:
F - 100 - ENT - DIE # - SPECIFIC DIE # - ENT.
The specifi c die selected and associated shut height value are now deleted.
6. Review All Programmed Dies and Positions: This is a read-only function. It provides a review of all existing
programmed die numbers *optional counter balance values and position values. In any mode depress: F - 1 - 7 - ENT.
The lowest die number will appear in the display followed by it's optional counter balance value then by it's corresponding
position. By pressing "ENT" the remaining die(s), optional counter balance(s) and shut height(s) will be displayed in numeri-
cally increasing order.
7. Ram "In Position" Window: This function puts an "In Position" window around each selected die position. It compensates
for small positional variations due to shock, temperature, etc. To use this function, select "PROG" mode and depress:
F - 1 - 8 - ENT - WINDOW ± VALUE - ENT.
When in the "AUTO" mode the Ram will move to the center of the window before stopping.
8. Jogging with System Errors: Should the transducer and/or cable become disabled, or it is desired to move the ram
beyond it's electronic limits this function allows the "JOG" keys to operate the slide in the manual mode. To access select
"JOG" mode and depress: F - 5 - 5 - 5 - ENT.
The manual jog keys will now activate the slide motors even though the display may not be providing position feedback or
the ram may be beyond it's limits.
Note: Extreme care must be taken when operating in this mode. This mode will be reset when the selector switch is rotated
out of the jog mode.
9. Counter Balance Override: Function #200 was added to allow for a counter balance override value. The counter
balance override value, once programmed in the PROG mode, is implemented instantly. Once a new die has been selected
in the AUTO mode, the new die's programmed counter balance value is implemented. The current counter balance value
can be viewed through Function #200 in any mode.
Example:
In PROG mode:
• enter the override counter balance value in Function #200 as 2.
<F> <2> <0> <0> <ENT>
<2> <ENT>
• enter die #1's position at 42.000 and set the counter balance to 10.
<F> <1> <ENT>
<DIE #> <1> <ENT>
<4> <2> <0> <0> <0> <ENT>
<1> <0> <ENT>
In AUTO mode:
• enter a die number.
<DIE #> <1> <ENT> <ENT>
Installation and Maintenance Manual