Akw M17 DigiPump Installation And User Care Instructions - Page 15
Browse online or download pdf Installation And User Care Instructions for Water Pump Akw M17 DigiPump. Akw M17 DigiPump 20 pages. Digipump
Care and Maintenance
Care and Maintenance
The integrity of the case and the RCD device operation should be checked quarterly as
part of a routine safety and maintenance activity on the installation.
If the case shows any mechanical damage the unit must be isolated electrically and the
entire unit replaced.
Pipework connections must be made to the unit with sufficient clearance (100mm
minimum separation to any pipe bend or fitting adjacent to the inlet/outlet connections) to
permit removal of the pump/head for routine maintenance and replacement.
The unit must be regularly cleaned using normal bathroom cleaning materials and rinsed
down with clean water and wiped dry with a soft cloth to remove any cleaning residue.
Do not use strong or concentrated acidic or alkaline cleaning materials as these may
discolour or otherwise damage the product. Do not use an abrasive cloth.
Installation Problems
Installation Problems
Please refer to pump instructions to ensure the pump is installed correctly.
Ensure flow sensor is connected to pump controller and power is on to pump controller.
Ensure that all pipe work is fully flushed before the flow sensor is installed, and
Check flow sensor is installed in the correct orientation
Most flow sensor problems are due to debris being caught inside the flow sensor.
PUMP WILL NOT START
the in-line filter is in place.
(Flow direction arrow moulded on the casing).
Remove sensor and check for debris.
If required reverse flush with water.
15