Flying Lemon cytrynka PDB User Manual - Page 12
Browse online or download pdf User Manual for Drone & Quadcopter Accessories Flying Lemon cytrynka PDB. Flying Lemon cytrynka PDB 20 pages. For power distribution board for zmr/qav/rcx 250 class copters
Current meter
cytrynka PDB has default on board current sensor with amperage up to 90A.
WARNING:
is designed to carry current only up to 60A.
There are two ways to get current value:
• soldering wire to pad on PDB and directly to OSD. In this case is not possible to
log current value
• using FC (default connection PDB->CB). In this case user must activate feature
in cleanflight configurator:
on image above in "Scale the output..." is "400" but must be 815!
or via CLI using commands:
feature CURRENT_METER
current_meter_type = 1
current_meter_scale = 815
current_meter_offset = 0
Current meter can work with amperage up to 90A but PDB
12