Ametek EN454 Service Manual - Page 4

Browse online or download pdf Service Manual for Blower Ametek EN454. Ametek EN454 14 pages.

Ametek EN454 Service Manual

Troubleshooting

POSSIBLE CAUSE
1.
* One phase of power line not connected
2.
* One phase of stator winding open
3.
Bearings defective
4.
Impeller jammed by foreign material
5.
Impeller jammed against housing or cover
6.
** Capacitor open
1.
* Two phases of power line not connected
2.
* Two phases of stator winding open
1.
Insufficient fuse capacity
2.
Short circuit
1.
High or low voltage
2.
* Operating in single phase condition
3.
Bearings defective
4.
Impeller rubbing against housing or cover
5.
Impeller or air passage clogged by foreign material
6.
Unit operating beyond performance range
7.
Capacitor shorted
8.
* One phase of stator winding short circuited
1.
Impeller rubbing against housing or cover
2.
Impeller or air passages clogged by foreign
material
3.
Bearings defective
1.
Leak in piping
2.
Piping and air passages clogged
3.
Impeller rotation reversed
4.
Leak in blower
5.
Low voltage
* 3 phase units
** 1 phase units
*** Disassembly and repair of new blowers or motors will void the Rotron warranty. Factory should be contacted
prior to any attempt to field repair an in-warranty unit.
Blower Disassembly:
WARNING: Attempting to repair or diagnose a blower may void Rotron's warranty. It may also
be difficult to successfully disassemble and reassemble the unit.
1) Disconnect the power leads. CAUTION: Be sure the power is disconnected before doing any work
whatsoever on the unit.
2) Remove or separate piping and/or mufflers and filters from the unit.
3) Remove the cover bolts and then the cover. NOTE: Some units are equipped with seals. It is
mandatory that these seals be replaced once the unit has been opened.
4) Remove the impeller bolt and washers and then remove the impeller. NOTE: Never pry on the
edges of the impeller. Use a puller as necessary.
5) Carefully note the number and location of the shims. Remove and set them aside. NOTE: If the
disassembly was for inspection and cleaning the unit may now be reassembled by reversing the
above steps. If motor servicing or replacement and/or impeller replacement is required the same
shims may not be used. It will be necessary to re-shim the impeller according to the procedure
explained under assembly.
OUT OF WARRANTY REMEDY ***
1.
Connect
2.
Rewind or buy new motor
3.
Change bearings
4.
Clean and add filter
5.
Adjust
6.
Change capacitor
1.
Connect
2.
Rewind or buy new motor
1.
Use time delay fuse of proper
rating
2.
Repair
1.
Check input voltage
2.
Check connections
3.
Check bearings
4.
Adjust
5.
Clean and add filter
6.
Reduce system pressure/vacuum
7.
Change capacitor
8.
Rewind or buy new motor
1.
Adjust
2.
Clean and add filter
3.
Change bearings
1.
Tighten
2.
Clean
3.
Check wiring
4.
Tighten cover, flange
5.
Check input voltage
3
Revised – February 2005