This operation must be carried out at the end of every season (provided the flue works properly, otherwise it must be
done more frequently).
Before replacing the hotplate rings, inspect the brick lining of the fire zone. Fine cracks in the lining are inevitable, and
do not affect stove operation. Minor damage can be repaired using refractory cement.
After cleaning the stove and all the parts described above, refit all the removed pieces, proceeding in reverse order.

5 TROUBLESHOOTING

5.17 The stove does not work

Make sure the connection and size of the flue are suitable for the stove's heating power.
Make sure the flue is constructed in conformity with the current regulations.
Make sure the flue inspection doors and openings are closed and sealed.
Make sure no other appliances are connected to the flue.

5.18 Difficult lighting

Open the primary air control and the damper.
Use wood and lignite blocks with a low moisture content.
Make sure the room ventilation ensures a sufficient amount of oxygen in the air.
Make sure the flue is suitable for the stove's heating power.

5.19 Smoke leaks

Check the flue draught.
Make sure the flue pipe connection complies with the seal requirements.
Make sure the ash does not obstruct the primary air grate.
Make sure combustion residuals do not block the flue pipe.
Make sure the primary air control is open.

5.20 The glass gets dirty quickly

Make sure the fuel is of a recommended type.
Make sure the wood is properly seasoned and dry.
Too much fuel in the combustion chamber.
Make sure the secondary air flow control is correctly adjusted.
Check the flue draught.

5.21 Condensate in the heating chamber

Make sure the procedure for first lighting has been carried out.
Make sure the fuel is of a recommended type.
Make sure the wood is properly seasoned and dry.
Make sure the flue is insulated and complies with the applicable standards.
Check the flue draught.

5.22 The oven does not heat

Make sure the oven door is properly closed.
Make sure the bypass damper is closed (pos. "Z")
Make sure the fuel burns normally.
Make sure there is sufficient flue draught.
Make sure the combustion fume ducts are clean.

5.23 The electric fan oven does not work

Check the electrical connection
Check correct operation of the controls, consulting this manual.

5.24 The gas hob does not work

Check the connection to the gas supply pipe.
Check correct operation of the controls, consulting the specific enclosed ILVE manual.
If the oven still does not work correctly, switch it off, disconnect the gas supply by closing the main cock and contact
the ILVE service centre.