Air Gunsa AZ3 HTE2 Instruction Manual
Browse online or download pdf Instruction Manual for Paint Sprayer Air Gunsa AZ3 HTE2. Air Gunsa AZ3 HTE2 9 pages. Spray gun
Also for Air Gunsa AZ3 HTE2: Instruction Manual (4 pages), Instruction Manual (17 pages)
Contacts:
ANEST IWATA Europe S.r.l.
46, Corso Vigevano 10155, Torino • ITALY
Direct Tel. +39 011 - 22 74 402
Fax +39 011 - 22 74 400
www.anest-iwataeu.com
ANEST IWATA ITALIA S.r.l.
46, Corso Vigevano 10155, Torino
• ITALY
Tel. diretto +39 011 - 24 80 868
Fax: +39 011 - 85 19 44
www.anest-iwata.it
ANEST IWATA Iberica
Calle de Les Teixidores, 3-5
08918 - Badalona (Barcelona)
• SPAIN
Tel.:+34 933 20 59 93
Fax.:+34 933 20 59 65
www.anest-iwata.es
ANEST IWATA Deutschaland
Mommsenstrasse 5, 04329 Leipzig
• GERMANY
Telefon: +49 0341 2414430
Fax: +49 0341 2525595
www.anest-iwata.de
ANEST IWATA Scandinavia
Ögärdesvägen 6C, 433 30 PARTILLE
• SWEDEN
Tel. +46 (0)31 - 340 28 60
Fax +46 (0)31 - 340 28 69
www.anest-iwata.se
ANEST IWATA France
25 rue de Madrid
38070 St Quentin Fallavier
• FRANCE
Tél. +33 (0)4 - 74 94 59 69
Fax +33 (0)4 - 74 94 34 39
www.anest-iwata.fr
ANEST IWATA U.K.
Unit 10 Little End Road - Eaton Socon
St. Neots - CAMBRIDGESHIRE
• U.K.
PE19 8JH
Tel.: +44 (0) 1480 405419
Fax: +44 (0) 1480 217610
[email protected] www.anest-iwata.co.uk
ANEST IWATA USA, Inc.
9920 Windisch Road,
• USA
West Chester, OH 45069
Tel: +1 513.755.3100
Fax: +1 513.755.0888
Toll Free: 800.440.0282
www.anestiwata.com
Cormack ANEST IWATA
Unit 3, 10 Boden Road,
SEVEN HILLS NSW 2147
• AUSTRALIA
Tel: +61 2 9853 2000
Fax: +61 2 9853 2090
www.anest-iwata.com.au
Model
AZ3 HTE2
Test
Transfer Efficiency according to EN 13966-1
Authority
IPA Fraunhofer Institut
Date
28/03/2008
T
ransfer efficiencies achieved with the materials detailed in the test report were:
THREE COAT SYSTEM
PRIMER
87 %
BASECOAT
83 %
CLEARCOAT
74 %
Certification available on www.airgunsa.com
ANEST IWATA Group
Air Gunsa S.r.l.
• ITALY
46, Corso Vigevano 10155 Torino
Quality Air Spray Guns Since 1944
Tel. +39 011 - 24 80 868
Fax +39 011 - 22 74 406
www.air-gunsa.com
Instruction Manual
SPRAY GUN AZ3 HTE2, AZ3 HTE2 AV, AZ3 HTE2 HVLP
Before use, adjustment or maintenance, it is important
GB
to read this instruction manual very carefully. This manual
must be stored in a safe place for any future reference.
This AIR GUNSA spray guns kit complies to
ATEX regulations 94/9/EC, protection level:
II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be diverted
to the ground via the conductive air hose as stipulated.
ALWAYS observe WARNINGS and CAUTIONS in this
instruction manual.
TECHNICAL SPECIFICATIONS
Max. working air pressure:
7.0 bar (100 PSI)
Air connection:
Noise Level (LAeqT)*:
77.6 dB (A)
Fluid connection:
Max. Temperature range:
5 ~ 40 °C
Weight g (lbs)**:
* Measuring point: 1m backwards from gun, 1.6m height
** Weight without cup.
Nozzle
Air pressure
Fluid
Air
Air cap set
Model
orifice
at gun inlet
output
consumption
mark
ø mm
bar (psi)
ml/min
Nl/min (cfm)
AZ3 HTE2 / AZ3 HTE2 AV Gravity feed
HTE 2 1.0 1.0 (0.039)
80
10-15
HTE 2 1.3 1.3 (0.051)
140
200 (7.06)
HTE
HTE 2 1.5 1.5 (0.059)
2.0 (29)
160
260 (10.23)
HTE 2 1.8 1.8 (0.070)
250
300 (11.81)
18-20
215 (7.59)
HTE
HTE 2 2.0 2.0 (0.079)
300
340 (13.38)
HTE 2 2.5 2.5 (0.098)
25 HTE
450
280 (9.89) 360 (14.17)
HTE 2 2.8 2.8 (0.110)
540
380 (14.96)
28-30
3.0 (44)
HTE
HTE 2 3.0 3.0 (0.118)
560
300 (10.59)
400 (15.74)
HTE 2 3.5 3.5 (0.138)
35 HTE
600
420 (16.53)
AZ3 HTE2 AV HVLP Gravity feed
The HVLP spray guns follows all compliant HVLP mandates. Follow the indications of
the inlet air pressure to achieve atomizing pressure of 0.7 bar (10 PSI) at the center of
the air cap.
HTE 2 HVLP 1.3 (0.051)
150
2.0 (29)
HTE 2 HVLP 1.5 (0.059)
185
HVLP
340 (12.0)
Air cap press.
HTE 2 HVLP 1.8 (0.070)
215
0.7 bar (10 psi)
HTE 2 HVLP 2.0 (0.079)
240
SAFETY WARNING
FIRE AND EXPLOSION
1. Never use the following HALOGENATED HYDROCARBON SOLVENTS:
which can cause cracks or dissolution of gun body (aluminium) due to
chemical reaction. UNSUITABLE SOLVENTS: methyl chloride, dichloro-
methane, 1.2-dichloroethane, carbon tetrachloride, trichloroethylene,
1.1.1-trichloroethane
2. Sparks and open flames are strictly prohibited. Paints can be highly
flammable and can cause fire. Do not expose to open flames, electrical
goods, cigarettes etc.
3. Securely ground spray gun using conductive air hose. (Less than 1MΩ)
Always ensure that the spray gun is earthed correctly.
Manufactured by: AIR GUNSA s.r.l, 46 Corso Vigevano 10155 Torino - Italy
HEADQUARTERS: ANEST IWATA Corporation
3176, Shinyoshida-cho, Kohoku-ku - Yokohama, 223-8501 JAPAN
PROTECTION OF HUMAN BODY
1. Use in a well-ventilated site, using a spray booth.
Poor ventilation can cause organic solvent poisoning and fire.
2. Always wear protective gear (safety glasses, mask, gloves) to avoid
inflammation of eyes and skin.
In case of any physical discomfort, immediately seek medical advice.
3. Noise level can exceed 85dB(A), wear earplugs if necessary.
4. Pulling the trigger many times during operation, may cause carpal
tunnel syndrome. Always rest, in case of tiredness.
G 1/4"M
G 1/4"F
IMPROPER USE
517 (1.14)
1. Never point gun towards people or animals.
Pattern
2. Never exceed maximum working pressure or maximum operating
width
Temperature
mm (in)
3. Always release air and fluid pressure before cleaning, disassembling
180 (7.08)
or servicing. Otherwise, remaining pressure can cause bodily injury due
to improper operation or scattering of cleaning liquid.
240 (9.44)
4. Tip of fluid needle set has a sharp point.
Do not touch the tip during maintenance to avoid accidents.
5. Never use this gun to spray foods or chemicals.
Otherwise, foreign substance, could cause corrosion of fluid passages
which could adversely affect health.
HOW TO USE
CAUTION
- Use clean air filtered through air dryer and air filter.
280 (11.0)
290 (11.4)
- When using this gun for the first time after purchase, adjust fluid nee-
dle packing nut, spray cleaner to clean fluid passages and remove rust
340 (13.4)
preventive oil.
360 (14.2)
1. Firmly connect an air hose to air nipple 1/4".
2. Firmly connect a suitable cup to fluid nipple.
3. Flush fluid passages with a compatible solvent.
4. Pour paint into container, test spray, adjust fluid output and pattern width.
HOW TO OPERATE
Suggested atomizing air pressure varies according to each model, and it
is listed in the Technical Data table.
Paint viscosity differs according to paint property and painting conditions.
12 to 23 sec. / Ford cup#4 is recommended.
Set the spray distance from the gun to the work piece, as near as possi-
ble within the range of 100-200 mm (3.9-7.9 in).
1