Dorf Napoleon Installation Instructions

Browse online or download pdf Installation Instructions for Kitchen & Bath Fixtures Dorf Napoleon. Dorf Napoleon 2 pages. Wall basin / bath mixer plumbers installation

NAPOLEON WALL BASIN/BATH MIXER
Important Information
HOT & COLD WATER INLET PRESSURES MUST BE EQUAL.
*
* Not suitable for gravity feed systems.
Basin outlet is fitted with a flow regulated aerator insert. This
*
low flow rate may not be suitable for connection to some
Instantaneous Gas Water Heaters, some Tempering Valves,
some Solar Water Heaters & some Thermostatic Mixing Valves.
Check with the manufacturers of these products. Note:- An
aerator insert kit (Part No. SP2001), is available if required.
For applications where flow regulation is not suitable (e.g. bath)
a full flow aerator insert has been provided within the packaging.
To convert the basin outlet to a bath outlet, refer to 'Replacing
Aerator Insert'
The wall outlet must be installed to the left hand side of the
*
handle (1) (Fig.3).
* Brazed connections should NOT be made directly onto the
mixer, as excessive heat will cause permanent damage.
* All pipework must be thoroughly flushed prior to installation,
as foreign materials may block the flow regulating device and
reduce the flow of water. Note: Aerator insert housing must be
retightened to prevent removal by hand.
Installation
1) Fit suitable fittings to the connection ports of the mixer (9) (Fig.2).
When facing the mixer, the connections should be as follows:
Hot water inlet connection 'H' to the left.
Cold water inlet connection 'C' to the right.
Mixed water outlet connection, vertically upwards.
+
Note: A suitable elbow fitting (13
) should be fitted to the hot inlet
(Fig. 2). Attach the mixer body (9) & the lugged elbow (12) to the
mounting plate (11) with screws (10) and tighten using a suitable
screw driver.
2)Fit the mounting plate (11) onto a suitable noggin in the wall &
secure using screws through the holes in each corner.
Important :
The mounting plate (11) must be installed horizontal & parallel
*
to the face of the wall studs to ensure correct installation.
To avoid damaging the decorative finish, do not remove the
*
protective sleeve until installation has been completed.
3)
Complete the connections. (Fig. 2). Check all connections for
leaks and the mixer for correct operation.
Note: Pipework and fittings are not supplied.
PLUMBERS INSTALLATION INSTRUCTIONS
IMPORTANT
Pressure & Temperature Requirements.
Hot and cold water inlet pressures should be equal.
Static inlet pressure range : 150 -1000 kPa
New Regulation :-500 kPa maximum static pressure
at any outlet within a building. (Ref. AS/NZS 3500.1)
Maximum hot water temperature : 80 C.
+ Not supplied.
4) Carefully slide the cover plate (5) onto the mixer body (9),
then push the cover plate firmly against the wall/tile face. (Fig. 1).
Check that the thread on the lugged elbow (12) is the correct
length as shown (Fig. 4). Cut to length if required ensuring
end face is square. Apply thread tape to the thread.
Important: Care must be taken that thread tape cannot
become dislodged and block the flow regulating device,
causing a reduction in water flow. To ensure correct
installation, length of exposed thread must not exceed 10mm.
5) Fit handle (1) taking care that it is pushed fully onto cartridge
stem, tighten screw (2) using the 2.5mm allen key (3) then fit
plug (4).
6) Screw the spigot (17) onto the thread of the lugged elbow (12)
using a 10mm allen key (15
securely against the wall/tile face. DO NOT OVERTIGHTEN.
Apply suitable lubricant to 'O'Rings (16).
7)
Fit wall outlet (14) onto the spigot (17), then carefully push it
firmly against the cover plate while tightening grub screws (21)
using the 2.5mm allen key (3) provided. Take care that the top face
of the wall outlet is horizontal before tightening screws (21). (Fig.4)
8)
Turn on Hot and Cold water supplies and check operation.
+
) untill the cover plate (5) is held
Replacing Cartridge (Fig. 1)
1) Turn off hot and cold water supplies.
2)
Carefully remove plug (4) before using a 2.5mm allen
key (3) to loosen grub screw (2) and remove handle
(1). Remove cap (6) taking care not to damage the
decorative finish. Unscrew nut (7) then lift out old
cartridge (8).
3)
Ensure inside face of mixer body (9) is clean. Check
that seal is in position in base of new cartridge (8).
Fit new cartridge (8) into mixer body (9), taking care
that two lugs on base of cartridge (8) fit into mating
holes in mixer body (9).
4) Screw on nut (7). Important:- Nut (7) should be
tightened to a torque of 10 Nm.
5)Replace cap (6), tightening by hand. Fit handle (1)
taking care that it is pushed fully onto cartridge stem,
then tighten grub screw (2) by using allen key (3).
Replace plug (4) taking care not to damage the
decorative finish.
6) Turn on water supplies and check operation.
Replacing Aerator Insert (Fig. 4)
1) Carefully remove aerator housing (20) from wall
outlet (14), taking care not to damage the decorative
finish.
2) Remove seal (18) & aerator insert (19) from aerator
housing (20). Check that aerator housing is clean.
Deposits of lime can be removed by washing in a
vinegar solution.
3) Fit new aerator insert (19) into aerator housing (20)
followed by seal (18) then screw assembly into wall
outlet (14) and tighten securely (to prevent removal by
hand).
(SHEET 1 OF 2)
IS1369A(12/14)