Canon LV-7565 Specification - Page 47
Browse online or download pdf Specification for Projector Canon LV-7565. Canon LV-7565 47 pages. Multimedia projectors
Also for Canon LV-7565: Brochure & Specs (6 pages), Brochure (6 pages), Specifications (6 pages)
Expand Serial Command Specification
9.12.6. CR_TEMPWARN Command
Command
"CR_TEMPWARN" [CR]
Read if the sensors are exceeding or approaching critical temperature.
Details
When some sensors are installed inside the Projector, read each sensor's
temperature.
Acceptable
Response
Unacceptable
9.12.7. CR_TEMPFAIL Command
Command
"CR_TEMPFAIL" [CR]
Read the temperature inside a Projector.
Details
When some temperature sensors are installed in the Projector, it is possible to
know the temperature all at once.
Acceptable
Response
Unacceptable
"000_%1_%2_%3" [CR]
%1: temperature sensor 1
%2: temperature sensor 2
%3: temperature sensor 3
"W" ---- Exceeding critical temperature (Warning)
"S" ----- Sensor temperature is safe
"N" ----- Not relate to the temperature
%1
%2
Ex. When "S_W_S" [CR] means that sensor 1 is saftety
%3
temperature, sensor 2 is exceeding critical temperature,
and sensor 3 is safety temperature.
Note) Depends on Projector models, when the temperature
difference between sensor 1 and sensor 2 is over the
specified temperature, the sensor may show "W". In this
case, sensor 3 shows that the temperature difference is
"W", "S", or "N".
"?" [CR]
"000_%1_%2_%3" [CR]
%1 = Temperature, sensor 1
%2 = Temperature, sensor 2
%3 = Temperature, sensor 3
(Ex.) "_31.5F" [CR]
_ means a space. When the temperature sinks to -, the first
character "-" like "-05.5F" [CR].
%1
Last character indicates the sensor's status.
%2
Exceeding critical temperature = "F"
%3
Sensor temperature is safe
Not relate to the temperature = "N"
"_31.5F" indicates 31.5 degrees and safety temperature.
When the temperature is safe, the data will be "_00.0S".
Every time the Projector is reset, "_00.0S" is set.
In short, previous data is deleted.
"?" [CR]
Page 46 of 46
= "S"