moves to Power OFF status due to power failure. Fan also stops unlike Cooling Down
status.
"28" [CR]
Status: Cooling Down in process due to Temperature Anomaly
When the inside temperature is out of the operating temperature, it automatically starts
Cooling Down. Response for this status is "28" [CR].
Even if the temperature decreases during this process, Cooling Down is executed.
"88" [CR]
Status: Coming back after temperature anomaly
When the status moves to Standby after Cooling Down due to temperature anomaly, it
returns "88" [CR].
This shows that the status turns to Standby because of abnormal temperature.
This status maintains until next operation is done. When Power On is executed, the
information of temperature anomaly is canceled and normal operation is executed.
"24" [CR]
Status: Processing Power Save / Cooling Down
Power management function in Setting menu works and the status goes to Power Save
/ Cooling Down.
During this time, Functional Execution Commands are invalid (not executed).
This status moves to Power Save at set hours after the operation of Cooling Down.
Status
No signal
Response
"00"
5 minutes with no signal
"04" [CR]
Status: Power Save
This shows that it moves to Power Save status by Power management function in
Setting menu.
"21" [CR]
Status: Cooling Down in process after turned off due to lamp failure
When a projector is turned off because of lamp failure, it automatically starts Cooling
Down operation, in which the projector returns "21" [CR].
"81" [CR]
Status: Standby after Cooling Down due to lamp failure.
This value is returned when Cooling Down operation due to lamp failure has been
completed and the status has been moved to Standby. The status is kept until the next
operation starts.
LV-8235 UST Basic Serial Command Specifications
Power Save / Cooling Down
"24"
-21-
Power Save
"04"
After about 90 sec.