Dormakaba ED connection board CAN Assembly Instruction Manual - Page 10
Browse online or download pdf Assembly Instruction Manual for Control Unit Dormakaba ED connection board CAN. Dormakaba ED connection board CAN 16 pages.
Connection
5 Connection
11
10
1
2
3
10
11
10
ED connection board CAN
1
43
3
64
63
1G
62
Number
43
3
64
63
62
1G
3
1
3
6
1
4
4a
1
15
17
3
1
11
13
3
35
41
42
3
2
3
3
1
3
6
1
4
4a
Assignment
Locking feedback
GND
NC
NO
COM
+ 24 V switched depending on the smoke detector
GND
+ 24 V
GND
Fire protection upgrade card
18k or RM ED
Shutdown drive function
GND
+ 24 V
Signal input safety sensor hinge side
Test output
GND
+ 24 V
Signal input safety sensor opposite side to the hinge
Test output
GND
Signal input night/bank
Signal input impulse outside
Signal input pulse inside
GND
Assembly Instruction
060636 45532/16923 - 2023-04