The operating conditions specified in the mounting and commissioning instructions
for ED 100/250 operators apply to the ED connection board CAN.
3.4 LED display
The RGB LED function display on the ED connection board CAN is defined as a
secondary function display. The RGB LED function display uses signal colors to
show the current operating status or a fault.
To see the signal colors of the RGB LED function display, remove the ED 100/250
operators' cladding.
Signal no. Color
1
2
3
4
See "Evaluate errors and rectify faults".
Signal no. Color
5
6
060636 45532/16923 - 2023-04
Layout
Ribbon cable connection socket
CAN connection cable EntriWorX connection terminals
CAN connection cable EntriWorX connection plug
Safety sensors
Signal inputs for night/bank, impulse outside and impulse inside
Description
permanently
Self-test error display
red
Flashing
Identification display
green
Flashing yel-
CAN device mapping
low
Flashing red Error display
Description
Glowing white
TMS initialization
Green light:
Display operating status
OK
Product description
Meaning
Self-test error occurred or
CAN device detection is
faulty.
The device identification is
activated.
The device assignment is ac-
tive after a CAN reset. De-
vice assignment ends when
the assignment is com-
pleted without errors or
when an error occurs.
One or more errors are
pending. Error number with
the highest priority is indi-
cated by the number of
flashes.
Meaning
TMS bus initialization for
sensor and ED connection
board CAN running.
The system is working with-
out errors.
ED connection board CAN
5