3.2 Acoustic element
The acoustic element is an aluminum frame that
holds a special foam to absorb sound. The acoustic
element must be fitted with a textile covering on site
to cover the foam and improve looks, and/or optional
LED lighting.
Installation conditions:
• A specially structured acoustic image (see below) is
attached to the dimpled acoustic foam for sound
absorption purposes.
• If absorption is only required on one side, an
advertising image can be used on the other side
(see below).
Technical information
Acoustic image
• Material: Textile Trevira CS 300g/m² white
• printed on one or both sides
• all-round welt edge 15 x 2.8 for frame
Advertising image
• Material: Deco light or Dynajet white
• printed on one or both sides
• all-round welt edge 15 x 2.8 for frame
Base profile with glass element
• Base profile 46, 10 - 13.5 mm glass thickness
• Base profile 46, 14 - 18 mm glass thickness
• 3 clamps per 1000 mm base profile
3.3 Sliding door system
MUTO L 80
A system for attaching a sliding door element made
of glass or wood in a UNIQUIN unit.
Installation conditions:
• If a door frame system is combined with a sliding
door in an escape route, then the track rail profile
for the sliding door is always on the opposite side to
the hinge of the glass or wooden door.
• The sliding door system includes door elements
made of glass or wood.
• A DORMOTION cushioning feature is optionally
available/retrofittable.
• The sliding door system features an integrated
locking device (optional/retrofittable).
Technical information
UNIQUIN System
Fig. 4
FH leaf height
FB leaf width
• FH max. = 3000 mm
• FB max. = 2000 mm
• FB min. = 660 mm
3.4 Door frame system for a
The door frame system consists of a door frame base
profile and a door frame cover profile with hinges for
fitting a glass door in a UNIQUIN unit.
Installation conditions:
• A glass door has the same thickness as the side
• Calculation of glass dimensions:
• If several doors (in frames) are installed in an
• Doors cannot be fitted with a wo-way function.
• A drop-down seal is retrofittable. (No special glass
• The door frame system can be combined with a
• The door frame system can be combined with
• The door frame system can be fitted to side panels,
WN 059609 45532
FB
FB
Dimensions of sliding door for passage
glass door
sections in the same escape route.
Glass width = door frame width – 86 mm
Glass height = door frame height – 50 mm
escape route, then these doors always open directly
to the inside or outside.
preparation is required. The door frame profile
needs to be adjusted, see installation manual.)
sliding track closer TS 97 (prepared glass and a door
frame profile need to be ordered).
electromodules (mounting element for a flush-
mounted socket or switch). The profile cross-section
accommodates cables with a diameter up to 10
mm.
with overpanel or directly to the wall.
Product description
2018-12