INTRODUCTION
The Advance Electric Combination boiler is perfect for modern all electric
apartment dwellers who prefer the comfort of wet central heating systems
and mains pressure hot water for powerful showers and quick bath filling.
The unit is supplied for use with a vented (open) central heating system and
also provides mains hot water. It should be installed so the top of the unit is
500mm above the top of the highest radiator. It can easily be converted to a
sealed system operation, please see page 11. It utilises off peak electricity for
economy in use and is pre-wired and pre-plumbed for ease of installation.
Two programmers are fitted to the unit, a timer for off peak (usually
overnight) electricity tariffs and a programmer for switching the central
heating on and off during the day. The central heating programmer/room
thermostat is wireless and can be used without the need for additional
wiring.The end user must set both of these.
There is sufficient hot water from an overnight charge for a shower and
a bath. A second immersion heater is fitted which should be wired to a
switched spur for hot water boost. If there are days when your hot water
needs increase this can be manually switched.
The product meets the HWA thermal store specification and parts G and L
of the Building Regulations.
The lower part of the store is dedicated to central heating. A 6kw
immersion heater is fitted for this purpose, and can be used in systems up
to four or five radiators. During start up periods the energy stored in the
lower part of boiler is ready for immediate use. If the water in the
radiators falls overnight to 20°C, for example, the 6kw heater is adequate
for demand of up to 10kw when first switched on in the day.
Note: Electrical repairs must only be undertaken by the manufacturer,
service agent or similarly qualified person in order to avoid a
hazard.
4