6
6.1 Description of the Supply control unit
The supply control unit includes:
*PROG. : programming button
*The kit does not require
programming. This
button is used only if you
add additional Terminals
or Panels to the system.
RED signaling
of PROG
= defect within
the system
TIME:
Lock timing adjustment
Check the precision of the connections in the system!
The +14V , GND , CD
Any short circuit between them leads to the non-operation of the entire system.
With an ohmmeter, check that there is no short circuit between any terminals, anywhere in the
system.
Make sure that the Torx screw of the Outdoor panel is completely screwed to prevent
turning on the anti-theft alarm.
Connect the Supply control unit to the 230 V AC network, by connecting the two automatic
10A fuses, installed on phase and null.
Optionally, connect the accumulator to the +ACC and –ACC terminals of the Supply control unit.
PAY AT TENTION to the polarity of the accumulator!
Check the existence of the supply tensions with the values mentioned below, at the terminals
of the Supply control unit (use a direct current voltmeter).
Tensions measured at the terminals of the Supply control unit : +14V
Ÿ
The tension +Uv
Ÿ
Tensions measured at the terminals of the Outdoor panel and at the terminals of the Terminals:
Ÿ
signals are common to all components of the system.
– GND
/ 13,5 ... 14,3V DC is not used by the audio systems.
S1: presence of tension
at the +14V - GND terminals
S2: existence of tension
at the +Uv - GND terminals
Protection lid for connections
+ 14V - GND min. 12 V DC
Protection lid for
connections
Front lid
GND / 13,8 ... 14,3V DC
EN
09