4 Device Installation
This section details installing the camera into a solid indoor ceiling.
Note:
•
The ceiling must be between 10.0 mm to 40.0 mm (0.40 in. to 1.57 in.) thick.
•
The ceiling must be capable of supporting a minimum of eight (8) times the weight of the camera
and bracket.
DO NOT connect the camera to the power supply during installation.
Warning: DO NOT connect the camera to the power supply during installation.
Warning: For units intended to be installed outdoors: All wiring connecting to the unit must be routed
separately inside a different permanently earthed metal conduits (not supplied).
Warning: Install external interconnecting cables in accordance to NEC, ANSI/NFPA70 (for US
application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in
accordance to local country codes for all other countries. Branch circuit protection incorporating a 20
A, 2-pole Listed Circuit Breaker or Branch Rated Fuses are required as part of the building installation.
A readily accessible 2-pole disconnect device with a contact separation of at least 3 mm must be
incorporated.
Note: Dahua recommends attaching a "drip loop" (flex or hard conduit) during installation to ensure
condensation does not form in the mount or the conduit.
Note: 24 VAC Class 2 power supply only.
Figure 4-1