Baumer GIM700DR Manual - Page 12
Browse online or download pdf Manual for Accessories Baumer GIM700DR. Baumer GIM700DR 32 pages. Dynamic inclination sensors with sae j1939 interface
Also for Baumer GIM700DR: Manual (16 pages)
Description of the NMT command
The commands are transmitted as unconfirmed objects and are structured as follows:
Identifier
Byte 0
COB-ID = 0
Command byte
The COB-ID for NMT commands is always zero. The Node-ID is transmitted in byte 1 of the NMT command.
Command byte
Command byte
Description
01h
Start remote node
02h
Stop remote node
80h
Enter pre-operational state
81h, 82h
Reset remote node
The node number corresponds to the Node-ID of the required users. With node number = 0, all users are
addressed.
NMT state event
Following initialization, the sensor is in the pre-operational state. In this status, SDO parameters can be read
and written. In order to request PDO parameters, the sensor must first be moved to the operational state.
Power on or hardware reset
Power on oder Hardware Reset
BootUp Message
4/5
Pre-Operational
1
4/5
Operational
The various NMT states
Init
Following initialization, the sensor logs on to the CAN bus with a Boot Up message. The sensor then goes
automatically to the pre-operational state.
Baumer_GIM700DR_CANopen_EN_V1.00_MNL.docx
27.04.21
Byte 1
Node-ID
Init
3
2
3
Stopped/Prepared
1
2
In state event drawing
1
2
3
4, 5
4/5
12/32
www.baumer.com