Baumer GNAMG. 223P Series Manual - Page 9

Browse online or download pdf Manual for Accessories Baumer GNAMG. 223P Series. Baumer GNAMG. 223P Series 19 pages. Inclination sensor with profibus-dp interface

Baumer GNAMG. 223P Series Manual
Parameter values of parameterization function (Set_Prm)
Parameter
Station status
Response monitoring
time
Minimum Station Delay
Responder
Ident No.
Group Ident No.
Operating parameter
Parameters of the
inclination sensor
Resolution
Baumer_GNAMG_Profibus_MA_EN
07.18
Data
Octet
Value range
type
Nr.
Octet
1
string
Octet
2 to 3
string
Octet
4
string
Octet
5 to 6
string
Octet
7
string
Octet
8
string
 Bit 0 = 0/1 inversion X-axis
 Bit 1 = 0/1 inversion Y-axis
 Bit 2 = 0/1 scaling X-axis
 Bit 3 scaling Y-axis
Octet
 Bit 4 = 0/1 standard
9
string
diagnosis/ extended
diagnosis
0x00 to 0x03
Octet
0x00 = 0.001° Resolution
10
string
0x01 = 0.01° Resolution
0x10 = 0.1° Resolution
0x11 = 1.0° Resolution
9/19
Default parameter
in GSD file
 Sync and freeze
mode supported
 Supported baud
rates
Profibus-specific data
Depending on Baud
rate
059B
00
Profibus-specific data
 less inversion
 less inversion
 less scaling
 less scaling
 extended
diagnosis
Default = 0x10 = 0.1°
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany