Baumer IO-Link RR30 Instruction Manual - Page 29
Browse online or download pdf Instruction Manual for Accessories Baumer IO-Link RR30. Baumer IO-Link RR30 40 pages. Radar sensor
![Baumer IO-Link RR30 Instruction Manual](/uploads/products/server2/1256754/1256754.jpg)
Parameter name
Analog
Output.AnalogMax
Analogue
Output.AnalogMin
Figure 26 Modified analog Output range
4.8.2.2 Distance at Analog Min/Max
With this parameters the analog output characteristic is set. By reducing the range the resolution of the
analogue output is changed, improved.
When to use: When the resolution of the analog output range should be improved.
en_BA_RR30_IO-Link_V0.23.docx
13.01.2021/
Short Description
Set the maximum value of the analog
output
Set the minimum value of the analog
output
Figure 27 Reduced sensing range for improved accuracy
Rights
rw
rw
29/40
Unit / Allowed Values
Limits: 4 - 20 mA, Default:
20mA
Limits: 4 20 mA, Default:
4 mA
Baumer Electric AG
Frauenfeld, Switzerland