Baumer O200 Instruction Manual - Page 9

Browse online or download pdf Instruction Manual for Accessories Baumer O200. Baumer O200 34 pages. Sensors with io-link

Baumer O200 Instruction Manual
4

Parameter

4.1 System Commands

A factory reset of the sensor activates the default parameters as programmed in the factory. All parameters
changed by the user will be lost.
Parameter name
Standard command

4.2 Measurement Data Channel (MDC)

Measurement Values

4.2.1
Parameter name
Measurement
Value.Intensity
Measurement
Value.Quality Value
en_BA_O200_IO-Link_V1.docx
15.08.2018/
Short Description
Restore Factory Settings
Short Description
Intensity measuring value
(Only available for O200.R)
The quality value represents the excess gain
ration in %
100 = Exactly the amount of light needed for a
switching operation
200 = Twice the amount of light needed
O200.G, O200.S:
Quality = Strength of received light / Strength
required
O200.R:
Quality = Intensity value / SSC1 SP1
9/34
Rights
Unit / Allowed
values
wo
Rights
Unit /
Allowed
values
0 ... 32000
ro
0 ... 32000
ro