8 Technical data

Measuring range MR
Min Teach-in range
1)
Resolution *
2)
Linearity error *
3)
Response time *
4)
Ambient light *
Typ. Temperature coefficient *
Light source
Laser class
Wave length
7)
Laser line*
high
width
Analog output
Load resistor U
Out
Load resistor I
Out
Alarm output
Voltage supply range
Supply current
Reverse polarity protection
Short circuit protection
Housing material
Tightening torque
Protection class
Temperature range
Storage temperature
vibrations stability
random stability
bump stability
Fault suppression
Manual_OADM20x659_DE_EN.doc
04.12.12
...6591
50...300 mm
≥ 5 mm
0.01...0.4 mm
± 0.2...± 1.5 mm
< 2 ms
≤ 100 kLux
± 0.03%
5)
MD/° C
6...11 mm
2 mm
If the laser beam is interrupted or if measurement faults occur, the analog outputs and the
alarm output remain at their most recent valid value for a max. of 300 ms. Every valid value
is immediately passed on to the outputs. If no valid value appears within 300 ms, the analog
outputs switch to 4 mA / 0 V and the alarm output goes to HIGH.
OADM 20I...
...6592
100...600 mm
≥ 10 mm
0.015...0.8 mm
± 0.5...± 3.4 mm
< 2.5 ms
≤ 100 kLux
± 0.03%
MD/° C
Red laser diode, pulsed
2
650 nm
7...17 mm
2 mm
4 ... 20 mA und 0 ... 10 V
> 100 kΩ
< (+Vs – 6 V) / 0.02 A
PNP / max. 100 mA
12 ... 28 VDC
< 100 mA, (bei + 24V ~ 40mA)
yes, Vs to GND
Yes
die-cast zinc
1.0 Nm
IP 67
- 20° C...+ 60° C
- 20° C...+ 70° C
IEC 60068-2-6
(30 g, 10-2000 Hz, per axis)
IEC 60068-2-64
(0,4 g2/Hz, 20-1000 Hz per axis)
IEC 60068-2-29
(75 g, 6 ms, 4000 pulse per axis and direction)
44/48
...6593
200... 1000 mm
≥ 20 mm
0.12...3 mm
± 0.36...± 9mm
< 3.5 ms
≤ 60 kLux
± 0.05%
MD/° C
8...25 mm
3...1 mm
Baumer
Frauenfeld, Switzerland