Baumer OXE7.E15T-11148276 User Manual

Browse online or download pdf User Manual for Accessories Baumer OXE7.E15T-11148276. Baumer OXE7.E15T-11148276 4 pages. Photoelectric sensors

Baumer OXE7.E15T-11148276 User Manual
Optoelektronische Sensoren
Photoelectric sensors
Détecteurs opto-électroniques
OXE7.E15T-11148276
Kanten-Sensoren
Edge sensors
Détecteur de bords
11148276
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Canada
Italy
Baumer Inc.
Baumer Italia S.r.l.
CA-Burlington, ON L7M 4B9
IT-20090 Assago, MI
Phone +1 (1)905 335-8444
Phone +39 (0)2 45 70 60 65
China
Singapore
Baumer (China) Co., Ltd.
Baumer (Singapore) Pte. Ltd.
CN-201612 Shanghai
SG-339412 Singapore
Phone +86 (0)21 6768 7095
Phone +65 6396 4131
Denmark
Sweden
Baumer A/S
Baumer A/S
DK-8210 Aarhus V
SE-56133 Huskvarna
Phone +45 (0)8931 7611
Phone +46 (0)36 13 94 30
France
Switzerland
Baumer SAS
Baumer Electric AG
FR-74250 Fillinges
CH-8501 Frauenfeld
Phone +33 (0)450 392 466
Phone +41 (0)52 728 1313
Germany
United Kingdom
Baumer GmbH
Baumer Ltd.
DE-61169 Friedberg
GB-Watchfield, Swindon, SN6 8TZ
Phone +49 (0)6031 60 07 0
Phone +44 (0)1793 783 839
India
USA
Baumer India Private Limited
Baumer Ltd.
IN-411038 Pune
US-Southington, CT 06489
Phone +91 20 2528 6833/34
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
1/4
OXE7.E15T-L82E.SIMD.7AI
Abmessungen
Dimensions
Dimensions
26
LED
4,3
4,5
2
19
M12 x 1
55
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
Technische Daten
Messbereich (Breite)
48 ... 72 mm
Messbereich (Abstand)
100 ... 150 mm
Messfrequenz
159 ... 625 Hz
1) 2)
kleinste erfassbare
0,7 mm
Stufe
Betriebsspannungsbe-
15 ... 28 VDC
reich +Vs
1)
Stromaufnahme max.
150 mA
(ohne Last)
Ausgangssignal
4 ... 20 mA /
0 ... 10 VDC
Schaltausgang
Gegentakt
verpolungsfest
ja, Vs zu GND
kurzschlussfest
ja
Fremdlichtsicherheit
< 35 kLux
Arbeitstemperatur
-20 ... +50 °C
Schutzart
IP 67
Technische Änderungen vorbehalten
Technical specifications subject to change
Elektrischer Anschluss
BN
(2)
Z
Z
GN
(3)
YE
(4)
GY
(5)
RS 485
WH
(1)
push-
PK
(6)
pull
RD
(8)
Z
Z
(7)
BU
1)
Class 2, UL 1310, see FAQ
CLASS 1 LASER
PRODUCT
IEC 60825-1/2014
Complies with 21 CFR 1040.10 and 1040.11
except for deviations pursuant to laser
notice No. 50, dated June 24, 2007
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technical data
measuring range (width)
48 ... 72 mm
measuring range (distance)
100 ... 150 mm
measuring frequency
159 ... 625 Hz
1) 2)
smallest detectable step
0,7 mm
voltage supply range +Vs
15 ... 28 VDC
1)
current consumption max.
150 mA
(no load)
output signal
4 ... 20 mA /
0 ... 10 VDC
switching output
push-pull
reverse polarity protection
yes, Vs to GND
short circuit protection
yes
ambient light immunity
< 35 kLux
operating temperature
-20 ... +50 °C
protection class
IP 67
Sous réserve de modifications techniques
Connection diagram
Schéma de raccordement
+Vs
analog
BN = Braun/brown/brun
GN = Grün/green/vert
out
YE = Gelb/yellow/jaune
alarm
GY = Grau/grey/gris
Rx/Tx-
WH = Weiss/white/blanc
PK = Rosa/pink/rose
Rx/Tx+
RD = Rot/red/rouge
sync in
0V
Données techniques
Plage de mesure (Largeur)
Plage de mesure (Distance)
Fréquence de mesure
Plus petit palier détectable
Plage de tension +Vs
1)
Consommation max. (sans charge)
Signal de sortie
Sortie commutation
Protégé contre inversion polarité
Protégé contre courts-circuits
Insensibilité à la lumière ambiante
Température de fonctionnement
Classe de protection
5
4
6
8
7
3
1
2
48 ... 72 mm
100 ... 150 mm
159 ... 625 Hz
1) 2)
0,7 mm
15 ... 28 VDC
150 mA
4 ... 20 mA /
0 ... 10 VDC
push-pull
oui, Vs vers GND
oui
< 35 kLux
-20 ... +50 °C
IP 67
15.11.2017