Baumer CANopen HMG 10 Installation And Operating Instructions Manual - Page 7

Browse online or download pdf Installation And Operating Instructions Manual for Media Converter Baumer CANopen HMG 10. Baumer CANopen HMG 10 36 pages. Absolute encoder with magnetic sensing

2.2
Attention instructions for mounting and operation
)
Risk of destruction due to electrostatic charge
Electronic parts contained in the encoder are sensitive to high voltages�
» Do not touch plug contacts or electronic components�
» Protect output terminals against external voltages�
» Do not exceed max� operating voltage�
)
Risk of destruction due to mechanical overload
Rigid mounting may give rise to constraining forces�
» Never restrict the freedom of movement of the encoder� The installation instruc-
tions must be followed�
» It is essential that the specified clearances and/or angles are observed.
)
Risk of destruction due to mechanical shock
Violent shocks, e� g� due to hammer impacts, can lead to the destruction of the
sensing system�
» Never use force� Assembly is simple when correct procedure is followed�
» Use suitable puller for disassembly�
)
Risk of destruction due to contamination
Dirt penetrating inside the encoder can cause short circuits and damage the optical
sensing system�
» Absolute cleanliness must be maintained when carrying out any work on the open
terminal box�
» When dismantling, never allow lubricants to penetrate the encoder�
)
Risk of destruction due to adhesive fluids
Adhesive fluids can damage the optical sensing system and the bearings. Dismoun-
ting an encoder, secured to a shaft by adhesive may lead to the destruction of the
unit�
» Do not use adhesive fluids for fixing.
MB250EN - 11173966, 17A2, Baumer_HMG10-CANopen_II_EN
SAFETy AND ATTENTION INSTRUCTIONS
4/33