9.4

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Speed (n):
• Range of switching speed (ns):
• Operating torque typ.:
• Rotor moment of inertia:
• Material:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Connection:
• Weight approx.:
MB072.1T2 - 11070663
n
ns´
ns
b)
Test conditions for switching speed
a)
Speed rise
b)
Speed rise
Baumer_HOG11-FSL-T2_II_DE-EN (20A1)
ø105 mm
ø12...20 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
≤450 N axial
≤600 N radial
IP67
≤1.25 · ns
850...4500 rpm (Δn = 2 rpm/s)
(as ordered)
6 Ncm
680 gcm
2
Housing: aluminium die-cast
Shaft: stainless steel
-40...+100 °C
-25...+100 °C (>3072 pulses per revolution)
-50...+100 °C (option heating)
IEC 60068-2-6
Vibration 5 g, 10-2000 Hz
IEC 60068-2-27
Shock 50 g, 11 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions CX (C5-M)
according to ISO 12944-2
2x terminal box
3x terminal box (option M)
2.2 kg, 2.4 kg (option M)
a)
t
Δn =
2 rpm/s
Δn =
1500 rpm/s
9
36