8.3
Settings of user adresses
ON
Last user
1
8.4
EMV-cable gland
The shielding of the contact cables must be done at the PG cable glands (PG7 and PG9).
The following are used:
1 x PG7 for voltage supply
2 x PG9 for data lines
Mounting:
foil,
Wire
Screen
ca. 5
20
15
Picture 1
The following cable cross-sections are admitted for the PGs:
PG7: Cable cross-section
PG9: 2-piece seal insert:
Manual_GXP6W_EN.doc
04.05.11
ON
User X
1
Strip the oversheath of the cable to ca. 35 mm (Picture 1), use connector sleeves
with litz cables. Push cap nut and seal insert onto cable sheath, shorten aluminum
if available, put braided screen over seal insert and shorten to 15 mm (Picture 2),
slide seal with cable into EMC PG cable gland and fix with cap nut.
Cable
- 4,0mm - 6,0mm
- 5,0mm - 7,0mm
- 7,0mm - 10mm
Wire
Alu film
Screen
Picture 2
11/14
Seal
Cable
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany