Baumer HMG 10 PROFINET Installation And Operating Instructions Manual - Page 17
Browse online or download pdf Installation And Operating Instructions Manual for Media Converter Baumer HMG 10 PROFINET. Baumer HMG 10 PROFINET 32 pages. Absolute encoder with magnetic sensing
5.1.2
Terminal assignment
)
Use connecting cable and connector exclusively in accordance to the
PROFINET directive�
5.1.2.1
Bus connecting box PROFINET [A]
5.1.2.2
Connector M12 [C] „Voltage supply" (male, 4-pin, A-coded)
4
1
5.1.2.3
Connector M12 [D] and [E] „Data transmission" (female, 4-pin, D-coded)
3
2
MB248EN - 11171699, 17A2, Baumer_HMG10-PROFINET_II_EN
MALE
CONNECTION DESCRIPTION
3
1
2
3
2
4
FEMALE CONNECTION DESCRIPTION
4
1
2
3
4
1
ELECTRICAL CONNECTION / PROFINET
Bus connecting box
PROFINET [ A ]
[ D ] [ E ]
[ C ]
UB
Voltage supply 10���30 VDC
-
Do not use
GND
Ground for UB
-
Do not use
TxD+
Transmission data+
RxD+
Receiving data+
TxD-
Transmission data-
RxD-
Receiving data-
14/29