Baumer HMG 10-Profibus DP Series Installation And Operating Instructions Manual - Page 12

Browse online or download pdf Installation And Operating Instructions Manual for Media Converter Baumer HMG 10-Profibus DP Series. Baumer HMG 10-Profibus DP Series 32 pages. Absolute encoder with magnetic sensing

MOUNTING / MOUNTING TO DRIVE SHAFT
4.3.2

Version with cone shaft

)
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error, see
page
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder.
» Lubricate drive shaft!
)
Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The encoder must be mounted with cable connection facing downward and not
exposed to water.
9/29
12�
10b
10c
10a
5
10e
10d
10c 10b
10b
9
10c
1�6x8 mm
MB246EN - 11171695, 17A2, Baumer_HMG10-ProfibusDP_II_EN
17 mm
7a
11b
11a
Mt = 3-4 Nm
10 mm
section 4.5,
TX 20
2
3
5 mm