Baumer HMG 10-SSI Installation And Operating Instructions Manual - Page 20
Browse online or download pdf Installation And Operating Instructions Manual for Media Converter Baumer HMG 10-SSI. Baumer HMG 10-SSI 36 pages. Absolute encoder with magnetic sensing
ELECTRICAL CONNECTION / VERSION RADIAL TERMINAL BOXES
5.6
Version radial terminal boxes
)
5.6.1
Cable connection
To ensure the speciied protection of the device the correct cable diameter must
be used�
Connecting cables are not in scope of delivery�
Mt = 2-3 Nm
TX 20
13
12
Cable shield
16/32
14
22 mm
Connecting terminal
irst terminal box [ A ]
See
section 5.6.2.1
section
15
Connecting cable
ø5-13 mm
or
5.6.2.2�
MB244EN - 11171691, 16A3, Baumer_HMG10-SSI_II_EN
12
Terminal box cover
13
Torx and slotted screw,
M4x32 mm
14
Cable gland M20x1�5 mm
for cable ø5-13 mm
15
Connecting terminal,
core cross-section ≤1.5 mm
Connecting terminal
second terminal box [ B ]
See
section 5.6.2.3
section
5.6.2.4�
2
or