Baumer HMG11 N13 Manual - Page 34
Browse online or download pdf Manual for Media Converter Baumer HMG11 N13. Baumer HMG11 N13 41 pages. Absolute encoders with profinet interface
6.4.8.
Parameter 971: Store Data
Read: The returned value indicates any transmitted but not yet saved parameter.
Parameter
Type
Data type
Value range:
Data: 971[0]
Write: The transmitted preset (Prm 65000) and the number of tolerated Master life sign failures (Prm
925) are saved non-volatile in the encoder memory
Parameter
Type
Data type
Value range:
Data: 971[0]
6.4.9.
Parameter 974: Base Mode Parameter
Read: Parameter „Base Mode Parameter Access service identification" is to read out three
parameter channel properties: maximum data length (240), Multi-Parameter-Access
capability (no) and maximum processing time to access (1000 x 10ms) for customer-specific
timeout.
Parameter
Type
Data type
Value range:
Data: 974[0]
974[1]
974[2]
6.4.10. Parameter 975: Encoder Object ID
Read: Parameter „Encoder Object Identification" is to read out Drive unit type, Data Object Type,
Firmware version and date as well as Drive Object (DO) Type Class, Subclass and ID.
See also parameter 964.
Parameter
Type
Data type
Value range:
Data: 975 [0]
975 [1]
975 [2]
975 [3]
975 [4]
975 [5]
975 [6]
975 [7]
975 [8]
975 [9]
Baumer_BUDE-PROFINET_MA_EN.docx
14.06.2016 / bja
971
Read / Write
unsigned int (0x06)
0x0000 – 0x0001
0x0000: no unsaved data present; 0x0001: unsaved data
971
Read / Write
unsigned int (0x06)
n/a
<empty>
974
Read only
unsigned int (0x06)
n/a
0x00F0
max. data length 240
0x0001
no Multi-Parameter-Access
0x03E8
max. processing time to access
975
Read only
unsigned int (0x06)
n/a
0x012A
MANUFACTURER_ID
0x0000
Drive Unit Type (manufacturer-specific)
0x0210
Firmware version (example only)
0x2015
Firmware year (example only)
0x1103
Firmware day and month (example only)
0x0005
Profidrive Type Class
0x8000
Profidrive DO Subclass 1
0x0001
Drive Object ID
0x0000
reserved
0x0000
reserved
34/41
www.baumer.com