Baumer HOG 100 Mounting And Operating Instructions - Page 29
Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer HOG 100. Baumer HOG 100 32 pages. Incremental encoder with axial terminal cover
Also for Baumer HOG 100: Installation And Operating Instructions Manual (32 pages), Mounting And Operating Instructions (32 pages)
10
Technical data
10.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
MB156a - 11069623
Baumer_HOG100-R_DE_EN_202201_MI_11069623 (22A1)
9...30 VDC (HTL)
9...26 VDC (TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
1024...10000 (as ordered)
90° ±8°
44...56 %
Zero pulse, width 90°
Optical
≤250 kHz
K1, K2, K0 + inverted
HTL
TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E217823
ø105 mm
ø16 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
(as ordered)
≤450 N axial, ≤600 N radial
IP66
≤10000 rpm (mechanical)
6 Ncm
320 gcm
2
Housing: aluminium die-cast
Shaft: stainless steel
-30...+85 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6, Vibration 20 g, 10-2000 Hz
IEC 60068-2-27, Shock 300 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex ec IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
(only with option ATEX)
Terminal cover
1.5 kg
10
Technical data
26