Baumer HOG 28 Mounting And Operating Instructions - Page 35

Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer HOG 28. Baumer HOG 28 40 pages. Incremental encoder with clamping set
Also for Baumer HOG 28: Installation And Operating Instructions Manual (36 pages), Mounting And Operating Instructions (36 pages)

Baumer HOG 28 Mounting And Operating Instructions
11

Technical data

11.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
11.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
MB178T2 - 11081759
9...26 VDC (HTL - version C, TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
1024...2048 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz
K1, K2, K0 + inverted
HTL
TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE
UL approval / E256710
ø287 mm
ø120...150 mm (through hollow shaft)
≤550 N axial
≤800 N radial
IP54
≤3600 rpm (mechanical)
50 Ncm
240 kgcm
Housing: aluminium alloy
Shaft: stainless steel
-30...+85 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 200 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
Flange connector M23, 12-pin (option M: 2x)
20 kg (ø150)
Baumer_HOG28-T2_II_DE-EN (19A1)
(ø150)
2
11
Technical data
32