10
Technical data
10
Technical data
10.1
Technical data - electrical ratings (HOG 60)
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2
Technical data - electrical ratings (HOGS 60)
• Voltage supply:
• Consumption w/o load:
• Sinewave cycles per turn:
• Phase shift:
• Reference signal:
• Sensing method:
• Output signals:
• Output stage:
• Difference of SinCos amplitude: ≤20 mV
• Harmonics typ.:
• DC offset:
• Bandwidth:
• Interference immunity:
• Emitted interference:
• Approvals:
21
9...26 VDC (HTL, TTL - version R)
5 VDC ±5% (TTL)
≤100 mA
200...10000 (As ordered)
90° ±8°
46...54%
Zero pulse, width 90°
Optical
≤250 kHz
A+, B+, R+, A-, B-, R-
HTL
TTL/RS422
(As ordered)
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE, UL approval / E256710
5 VDC ±10 % (version DN ...)
9...30 VDC (version DN ... R)
≤90 mA
1024...2048 (As ordered)
90°
Zero pulse, width 90°
Optical
A+, B+, R+, A-, B-, R-
SinCos 1 Vpp
-50 dB
≤20 mV
250 kHz (-3 dB)
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE, UL approval / E256710