10
Technical data
10.1
Technical data - electrical ratings
Voltage supply:
Consumption w/o load:
Pulses per revolution:
Phase shift:
Duty cycle:
Reference signal:
Sensing method:
Output frequency:
Output signals:
Output stages:
Interference immunity:
Emitted interference:
Approvals:
10.2
Technical data - mechanical design
Size (flange):
Shaft type:
Shaft loading:
Protection DIN EN 60529:
Operating speed:
Operating torque typ.:
Rotor moment of inertia:
Materials:
Operating temperature:
Resistance:
Corrosion protection:
Explosion protection:
Connection:
Weight approx.:
MB049 - 11114026
Baumer_HOG22_II_DE-EN (17A1)
9...30 VDC (HTL, TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
720...4000 (As ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz
K1, K2, K0 + inverted
HTL
TTL/RS422
(As ordered)
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE, UL approval / E256710
ø227 mm
ø80...115 mm (through hollow shaft)
≤450 N axial; ≤700 N radial
IP54
IP56
(As ordered)
≤3800 rpm (mechanical)
50 Ncm
102 kgcm
2
Housing: aluminium
Shaft: stainless steel
-30 °C...+85 °C
Restricted in potentially explosive environments, see
IEC 60068-2-6:2007
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 200 g, 6 ms
IEC 60068-2-52 Salt mist
Complies to ISO 12944-5:1998
Protective paint systems (C4)
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
Terminal box
2x terminal box (with option M)
Plug-in electronics with angle flange connector (option)
8,6 kg (ø100)
10
Technical data
section
2.
30